Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
RGO (Porto Alegre) ; 67: e20190038, 2019. tab
Article in English | LILACS | ID: biblio-1040936

ABSTRACT

ABSTRACT Objective The purpose of the present study was to evaluate the knowledge of Dentistry and Physical Education students on mouthguard usage in sports practice. Methods A form containing questions that demonstrated participants' knowledge about the use of mouthguards was applied. Inclusion criteria were: individuals older than 18 years who were attending Dentistry or Physical Education courses from the sixth period and who agreed to participate in the study, and the exclusion criteria for dentistry students were: attended the discipline of Dental Materials II of UFPE and already participated in internships in schools or academies for the participants of the Physical Education course. Results it was possible to observe that 97% of the interviewees know what a mouthguard is, but none of the participants would be able to indicate a specific type of mouthguard to sportsmen. Conclusion It was possible to conclude that a large number of the interviewees know what a mouthguard is, but not enough to indicate which is the safest protector.


RESUMO Objetivo Avaliar o conhecimento dos alunos do curso de Odontologia e Educação Física sobre os protetores bucais nos desportos. Métodos Aplicação de formulário avaliando conhecimento dos participantes sobre o uso de protetores bucais. Os critérios de inclusão foram: indivíduos maiores de 18 anos que estivessem cursando os cursos de Odontologia ou Educação Física a partir do sexto período e que concordassem em participar da pesquisa, já os critérios de exclusão para os alunos do curso de Odontologia foram: não ter cursado a disciplina de Materiais Dentários II da UFPE e já ter participado de estágios em escolas ou academias no caso dos participantes do curso de Educação Física. Resultados: foi possível observar que 97% dos entrevistados sabem o que é um protetor bucal, porém, nenhum dos participantes saberiam indicar um tipo específico de protetor bucal aos desportistas. Conclusão que uma grande parcela dos entrevistados conhece o que é um protetor bucal, porém, não o suficiente para poder indicar qual o protetor mais seguro.

2.
Rev. odontol. UNESP (Online) ; 48: e20190078, 2019. tab, graf
Article in Portuguese | LILACS, BBO | ID: biblio-1043179

ABSTRACT

Resumo Introdução Historicamente, materiais abrasivos, como mármore em pó, corais e cinzas ósseas, eram utilizados para higienização dentária. Com a evolução, tais materiais foram substituídos por dentifrícios aplicados em escovas dentais, com a mesma finalidade. Objetivo Avaliar, através da Tomografia por Coerência Óptica, o desgaste do esmalte dentário, após o uso de diferentes escovas dentais e materiais utilizados na escovação com componentes abrasivos. Material e método Foram confeccionados 50 corpos de prova, distribuídos em 10 grupos (n=5), de acordo com o dentifrício/escova utilizado. Para o grupo A, foi utilizada a escova dental Curaprox® Adulto Ultra Macia, e, para o grupo B, a escova Dental K® - escova adulto macia. Foram utilizados os seguintes materiais para escovação: Curaprox® Black is White; Colgate® Luminous White Instant, Close Up® White Attraction - MenSuperpure; Carvão Ativado; Água Destilada. As imagens foram realizadas antes e depois da ciclagem de escovação e comparadas quanto às alterações de superfície. A perda da estrutura superficial foi avaliada através dos métodos qualitativo e quantitativo. Para análise estatística dos dados obtidos, foram realizadas as medidas estatísticas: média, desvio padrão, mediana e percentis, avaliados inferencialmente através dos testes estatísticos Mann-Whitney, Kruskal-Wallis, com nível de significância de 5%. Resultado Maior índice de perda de estrutura superficial do esmalte nos grupos G2A (16,09) e G2B (11,38) e menor índice de perda estrutural nos grupos G5A (1,07) e G5B (1,20). Conclusão: Através desse estudo, observou-se que os dentifrícios clareadores e o Carvão Ativado são capazes de promover intenso desgaste do esmalte dentário.


Abstract Introduction Historically, abrasive materials such as marble powders, corals and bone ashes were used for dental hygiene. With evolution, these materials were replaced by dentifrices applied on toothbrushes for the same purpose. Objective To evaluate, through Optical Coherence Tomography, the wear of dental enamel after the use of different toothbrushes and materials used in brushing with abrasive components. Material and method 50 specimens were prepared, distributed in 10 groups (n=5) according to the toothpaste used. For group A, the Curaprox® Adult Ultra Macia toothbrush was used and for group B, the soft toothbrush K® - soft adult toothbrush. The following brushing materials were used: Curaprox® Black is White; Colgate® Luminous White Instant, Close Up® White Attraction - MenSuperpure; Activated Charcoal; Distilled Water. The images were performed before and after the brushing cycle and were compared for surface changes. The loss of the surface structure was evaluated through qualitative and quantitative methods. Statistical analysis of the data was performed using the statistical methods Mann-Whitney, Kruskal-Wallis, with significance level of 5%, mean, standard deviation, median and percentiles. Result A higher index of loss of enamel structure was observed in the G2A (16.09) and G2B (11.38) groups and a lower structural loss rate in the specimens corresponding to the groups G5A (1,07) and G5B (1,20). Conclusion Through this study it was observed that the whitening dentifrices and the Activated Charcoal are able to promote an intense wear of the dental enamel.


Subject(s)
Tooth Abrasion , Dental Enamel , Dentifrices , Tomography, Optical Coherence , Toothbrushing , In Vitro Techniques , Charcoal
3.
Rev. odontol. UNESP (Online) ; 45(6): 351-355, nov.-dez. 2016. tab
Article in Portuguese | LILACS, BBO | ID: biblio-830705

ABSTRACT

Objetivo: Avaliar os aparelhos fotopolimerizadores utilizados em clínicas da cidade do Recife e a manutenção realizada nesses aparelhos. Método: Os profissionais participaram da avaliação de forma voluntária e não foram identificados nos questionários que foram por eles respondidos. Foi perguntado sobre os métodos de desinfecção, a frequência de troca de lâmpadas e a frequência da técnica empregada de manutenção. Também foi realizada a avaliação do aparelho fotopolimerizador, registrando as informações referentes a modelo, marca e data de aquisição. Foi realizada a mensuração da intensidade de luz utilizando-se um radiômetro (Demetron®). Resultado: Todos os aparelhos fotopolimerizadores estavam com intensidade de luz inferior a 300 mW/cm2; 96,7% dos profissionais realizavam manutenção técnica de seus aparelhos apenas quando necessário; 100% trocavam a lâmpada só quando a mesma queimava; 40% dos aparelhos fotopolimerizadores encontravam-se acoplados ao equipo; 86,6% dos aparelhos apresentavam detritos na fibra óptica; 50% dos filtros apresentavam fraturas, sendo que 86,66% dos mesmos apresentavam detritos; 60% dos profissionais empregavam apenas álcool 70° como método de desinfecção; 53% dos entrevistados realizavam o método de desinfecção após cada paciente. Conclusão: Todos os aparelhos fotopolimerizadores avaliados estavam com intensidade de luz abaixo do preconizado e constatou-se a inexistência de um protocolo de manutenção preventiva periódica.


Objective: To evaluate the light curing equipment used in the Recife city clinics and maintenance performed on these devices. Method: The professionals participated in the evaluation voluntarily and were not identified in the questionnaires that were answered by them. He was asked about the disinfection methods, the frequency of changing bulbs and the technique often employed maintenance. It also promoted the evaluation of the curing light recording the information on the make, model and date of purchase. Measuring the light intensity using a radiometer (Demetron®) it was performed. Result: All light curing units were light intensity with less than 300mW/cm2; 96.7% of professionals performed the servicing of your appliances only when necessary; 100% exchanged the lamp only when it burned, 40% of light curing units found themselves attached to dental chair; 86.6% of the debris had apparatus in the optical fiber; 50% of filters had fractures, 86.66% of them had debris; 60% of professionals employed only 70° alcohol as disinfection method; 53% of respondents performed the disinfection method after each patient. Conclusion: All light curing units were evaluated with light intensity below the recommended and the absence of a periodic preventive maintenance protocol.


Subject(s)
Surveys and Questionnaires , Composite Resins , Dental Clinics , Dentistry , Light
4.
Rev. ABO nac ; 19(5): 275-280, out.-nov. 2012. tab
Article in Portuguese | LILACS, BBO | ID: lil-671907

ABSTRACT

Introdução - O presente estudo avaliou a resistência adesiva do adesivo Clearfil SE Bond (Kuraray), quando aplicado à dentina tratada com diferentes agentes condicionadores e em dois períodos de tempo de armazenamento, usando terceiro molares humanos recém-extraídos. Material e métodos - Os dentes foram divididos aleatoriamente em 6 grupos: grupo 1 - Clearfil SE Bond usado como recomenda o fabricante e armazenado por 24 hs; grupo 2 - Clearfil SE Bond associado ao ácido poliacrílico armazenado por 24 hs; grupo 3 - Clearfil SE Bond associado ao EDTA e armazenado por 24 hs; grupo 4 - Clearfil SE Bond usado como recomenda o fabricante e armazenado por 6 meses; grupo 5 - Clearfil SE bond associado ao ácido poliacrílico e armazenado por 6 meses e grupo 6 - Clearfil SE Bond associado ao EDTA e armazenado por 6 meses. Após o preparo da dentina foi construído sobre a área de adesão um cilindro de resina composta Z250 (3M/ ESPE). Os corpos de prova foram submetidos ao teste de cisalhamento em máquina de ensaio universal Kratos com velocidade de 0,5 mm/ min. Resultados - Os valores médios encontrados em MPa foram: G1= 29,91±5,84; G2= 31,66±6,44; G3= 33, 84±4,87; G4= 29,11±9,52; G5= 27,20±7,64 e G6= 31,45±7,19. Foi utilizado o teste ANOVA através do teste F (P<0,05), não se observou diferença estatística significante entre os grupos. Conclusões - Concluiu-se que a utilização de substâncias condicionadoras associadas ao adesivo Clearfil SE Bond não interferiu na resistência adesiva e que não houve redução da resistência adesiva após o período de 6 meses.


Introduction - The present study assessed the bond strength of Clearfil SE Bond (Kuraray), when applied to dentin treated with different conditioning agents and two periods of storage time,using recently extracted human third molars. Material and methods - The teeth were randomly divided into six groups: Group 1- Clearfil SE Bond used according to the manufacturer’s recommendations and stored for 24 h; Group 2- Clearfil SE Bond associated to polyacrylic acid and stored for 24 h; Group 3- Clearfil SE Bond associated to EDTA and stored for 24 h; Group 4- Clearfil SE Bond used according to the manufacturer’s recommendations and stored for six months; Group 5- Clearfil SE Bond associated to polyacrylic acid and stored for six months; Group 6- Clearfil SE Bond associated to EDTA and stored for six months. After the preparation of the dentin, a composite resin cylinder was constructed over the adhesion areaZ250 (3M/ ESPE). Results - The specimens were submitted to the shear bond test using the Kratos universal testing machine at a velocity of 0.5 mm/min. The mean values in MPa were:G1= 29.91±5.84; G2= 31.66±6.44; G3= 33.84±4.87; G4= 29.11±9.52; G5= 27.20±7.64 and G6= 31.45±7.19. ANOVA with the F test (p<0.05) revealed no statistically significantdifferences between groups. Conclusion - It was concluded that the use of conditioning substances associated to the Clearfil SE Bond adhesive did not affect bond strength and there was no reduction in bond strength after a period of six months.


Subject(s)
Humans , Male , Female , Dentin-Bonding Agents/chemistry , Dental Enamel , Dentin , Shear Strength
5.
Rev. ABO nac ; 19(1): 51-54, fev.-mar. 2011. ilus
Article in Portuguese | LILACS, BBO | ID: lil-667644

ABSTRACT

Devido a fatores econômicos, sociais e culturais, as pessoas ao longo do tempo perdem seus dentes ainda jovens, e boa parte dessas pessoas já foi submetida à terapia com dentaduras. Porém, outras sequer tiveram condições de acessar esta alternativa terapêutica. Ao longo dos anos, os processos alveolares (especialmente os inferiores) sofreram reabsorção e, hoje, essas pessoas, já na terceira idade, não dispõem de estrutura óssea capaz de promover estabilidade às suas próteses (quando as possuem), ficando, consequentemente, prejudicadas em sua função mastigatória, em sua fonação, e em seu convívio social pela impossibilidade de uso da dentadura inferior, causando-lhe prejuízo estético e, muitas vezes, psicológico em razão da baixa autoestima, além de exigirem um trabalho maior do aparelho digestivo no tratamento do bolo alimentar ingerido sem a adequada mastigação. Os projetos de extensão universitária representam, na essência do termo, a projeção que a instituição de forma geral e os componentes desta, de forma individual, estabelecem com o meio social onde estão inseridos, instaurando um ciclo de retroalimentação, teoricamente positivo, que justificaria a existência da Universidade na sociedade. Não se conceitua a Universidade que não exerce o seu papel transformador dentro da sociedade O presente trabalho objetiva mostrar através de apresentação de um caso clínico de overdenture sobreimplantes, a importância dos projetos de extensão envolvendo parcerias institucionais na melhoria da qualidade de vida da população.


Due to various factors, including the economic, social and cultural perspective, many people ended up losing their teeth at a young age and good parts of these people underwent therapy with dentures. Others were even able to access this alternative therapy. Over the years, the alveolar processes (especially the lower) showed resorption and now these people, because the elderly do not have the bone structure that promotes stability of their prostheses (when have one), being thushindered in its function mastication, in his speech and in their social life by the impossibility of using the lower denture, causing disfigurement and psychological often because of low self-esteem, and require a greater work of the digestive tract in the treatment of swallowed bolus without proper chewing.The university extension projects represent the essence of the term, the projection that the institution in general and components that, individually, lay with the social environment where they fit, introducing a feedback loop, positive theory, would justify the existence University of society. Not that conceptualizes the University shall not exercise its transformative role in society This paper aims to show through the presentation of a clinical case of overdenture implant the importance of the extension projects involving institutional partnerships to improve the quality of life.


Subject(s)
Humans , Female , Dental Implants , Denture, Complete , Motivation
6.
Rev. odontol. UNESP (Online) ; 39(1): 49-54, jan.-fev. 2010.
Article in Portuguese | LILACS, BBO | ID: biblio-874774

ABSTRACT

O material obturador ideal deve apresentar características específicas, como biocompatibilidade, selamento marginal adequado, capacidade de permitir ou induzir o reparo ósseo e facilidade de manipulação e inserção. O agregado trióxido mineral (MTA) foi desenvolvido como um material para obturação retrógrada com melhores propriedades químicas, físicas e biológicas do que os materiais existentes na época, como amálgama, material restaurador intermediário (IRM) e SuperEBA. Atualmente, o MTA é usado como material de preenchimento radicular no selamento apical, no reparo de perfurações e como agente de capeamento pulpar, além de ser usado como material de obturação retrógrada. O objetivo deste artigo foi realizar uma revisão da literatura acerca do agregado trióxido mineral, comparando-o com os principais cimentos endodônticos e materiais obturadores retrógrados disponíveis no mercado para a retrobturação do sistema de canais radiculares, analisando suas propriedades e características biológicas. Concluiu-se que o MTA é um material obturador retrógrado bastante satisfatório do ponto de vista químico-físico-biológico, especialmente por sua biocompatibilidade e seu potencial de ação osteocondutora, osteoindutora e cementocondutora.


The ideal root canal sealer should present specific characteristics, as biological compatibility, appropriate marginal sealing, ability to allow or induce bone repair, and ease of manipulation and insertion. Mineral trioxide aggregate (MTA) was developed such a retro-sealer with better chemistry, physics and biological properties than materials that exist at the time, as amalgam, intermediate restorative material (IRM), and SuperEBA. Actually, MTA is used such a canal filling material to seal root apical, at drilling repair, and as a pulp capping agent; in addition, it is used as a filling retrograde material. The purpose of this study was a literature review about mineral trioxide aggregate, comparing it to the main endodontic cements and retro-sealer materials available at market for root canal filling retrograde filling, analyzing its properties and biological characteristics. It was concluded MTA is a quite satisfactory retro-sealer material, in terms of its chemical-physical-biological properties, especially due to its biocompatibility, and potential actions do conduce and induce the repair of bone and cementum.


Subject(s)
Humans , Root Canal Filling Materials , Dental Leakage , Dentistry, Operative , Dental Pulp Capping , Retrograde Obturation
7.
Rev. odontol. UNESP ; 35(4): 293-298, out.-dez. 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-858468

ABSTRACT

A proposta do trabalho foi avaliar o grau de microinfiltração marginal do sistema adesivo Single Bond (3M ESPE) por meio de dois diferentes tipos de fotopolimerizadores. Foram utilizados dez pré-molares humanos e confeccionadas cavidades do tipo classe II, sendo uma ocluso-mesial e outra ocluso-distal, com término oclusal em esmalte e término cervical localizado em cemento, em seguida, restauradas com Single Bond (3M ESPE) e resina composta Filtek Z250 (3M ESPE) cor A2. Os dentes foram divididos em dois grupos: Grupo 1 û fotopolimerizado com o aparelho de luz halógena Optilight (Gnatus); Grupo 2 û fotopolimerizado com o aparelho sem fio LED Radii (SDI). Os dentes e os forames apicais foram isolados, deixando exposta à margem de 1,0 mm ao redor da restauração, sendo em seguida termociclados 250 vezes (±5°C e ±55°C). Após, os corpos-de-prova foram mergulhados em solução de fucsina básica a 0,5 porcento por 48 horas para posterior avaliação obedecendo aos escores: grau 0 û ausência de infiltração; grau 1 û infiltração até 1/3 da parede; grau 2 û infiltração entre 1/3 a 2/3 da parede e grau 3 û infiltração mais do que 2/3 da parede. Os escores para dentina foram: G1: 0 = 100 porcento; G2: 0 = 70 porcento; 1 = 10 porcento; 2 = 20 porcento. Para esmalte: G1: 0 = 90 porcento; 1 = 10 porcento; G2: 0 = 50 porcento; 2 = 20 porcento; G3 = 30 porcento. Os resultados foram submetidos à análise estatística de Mann-Whitney (p < 0,05), demonstrando não haver diferença estatisticamente significante entre os grupos. Concluiu-se que a microinfiltração marginal não foi influenciada negativamente quando foi empregada a unidade fotopolimerizadora LED


The purpose of this study was to evaluate the microleakage of the bonding system Single Bond (3M ESPE) when used 2 differents light-curing units. Class II cavities were prepared in 10 human premolars. After, the cavities prepared were treated with the bonding agent Single Bond (3M ESPE) and filled with Filtek Z250 (3M ESPE) composite resin, color A2. The teeth were divided into 2 groups: G1 ­ the restorations were light-cured with a conventional halogen-based light-curing unit (Gnatus); G2 ­ the restorations were cured with a LED cordless light-curing unit Radii (SDI). The specimes were thermo-cycled 250 cycles (± 5 °C and ± 55 °C) prior to immersion in 0.5% basic fuchsin for 48 hours for posterior evaluation. The scores in dentin were: G1: 0 = 100%; G2: 0 = 70%; 1 = 10%; 2 = 20%. In the enamel: G1: 0 = 90%; 1 = 10%; G2: 0 = 50%;­ 2 = 20%; G3 = 30%. The data were subjected to statistical analysis using Mann-Whitney test (p < 0.05) and showed no significant statistical difference between the groups. In conclusion the LED light source no influenced the microleakage


Subject(s)
Humans , Dental Leakage , Dental Restoration, Permanent , Light-Curing of Dental Adhesives , Curing Lights, Dental , Polymerization , Composite Resins , Bicuspid , Dentin-Bonding Agents , Statistics, Nonparametric
8.
JBC j. bras. clin. odontol. integr ; 10(53): 149-154, abr.-jun. 2006. tab, graf, ilus
Article in Portuguese | LILACS, BBO | ID: lil-518328

ABSTRACT

O propósito deste estudo foi avaliar a resistência ao cisalhamento dos sistemas adesivos Single Bond (3M ESPE) e Bond 1 (Jeneric/Pentron) após a aplicação na dentina do agente dessensibilizante Gluma Desensitizer (Kulzer). Foram utilizados 20 terceiros molares humanos hígidos, extraídos por motivos terapêuticos, os quais foram armazenados em soro fisiológico. Os dentes foram lixados com lixa d'água de granulação #100, #320, #600, respectivamente, para obter uma superfície plana e lisa. A área de adesão foi delimitada com um círculo de papel adesivo (contacto), contendo uma perfuração central de 2,34 mm de diâmetro. Grupo 1: Controle (Bond 1); Grupo 2: (Gluma + Bond 1) aplicação do Gluma por 60 s, secar por 30s, lavar por 10s, secar por 5s; Grupo 3: Controle (Single Bond); Grupo 4: (Gluma + Single Bond) aplicação do Gluma por 60s, secar por 30s, lavar por 10s, secar por 5s. A resina Filtek Z250 (3M ESPE) cor B2 foi aplicada com o auxílio de uma espátula de teflon sobre a superfície dentinária. Os corpos de prova foram armazenados em água destilada a 37ºC por 24 h. A resistência ao cisalhamento foi determinada na máquina KRATOS 2000 a uma velocidade de 0,5 mm/min. Os resultados em MPa foram (média +- D. P.): Grupo 1 (14,47 +- 5,02); Grupo 2 (15,60 +- 2,74); Grupo 3 (16,74 +- 4,06); Grupo 4 (14,90 +- 3,78). Os dados foram analisados pelo teste ANOVA. A análise estatística demonstrou não haver diferença estatística entre os grupos. Conclui-se que o agente dessensibilizante Gluma Desensitizer não influenciou significativamente na força de adesão dos sistemas adesivos.


Subject(s)
Dentin Sensitivity , Dentin-Bonding Agents , Shear Strength , Analysis of Variance , Dentition, Permanent , Hypersensitivity
9.
Rev. odontol. UNESP ; 34(3): 113-118, jul.-set. 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-519055

ABSTRACT

O objetivo deste trabalho foi avaliar com auxílio de um radiômetro, os aparelhosfotopolimerizadores utilizados nas clínicas e nos consultórios particulares da cidade de Caruaru-PE, e a manutenção realizada nesses aparelhos. Foram avaliados 60 fotopolimerizadores. Todosos profissionais participaram da avaliação de forma voluntária e não foram identificados nosquestionários que foram por eles respondidos. Foi perguntado sobre os métodos e a freqüência delimpeza e manutenção empregados, o nível de satisfação com o desempenho do aparelho, o nívelde conhecimento e atualização sobre o tema estudado e, finalmente, a técnica de fotopolimerizaçãoutilizada. Também foi realizada a avaliação do aparelho fotopolimerizador anotando-se asinformações referentes a tipo e diâmetro da ponta fotopolimerizadora, modelo, marca e datade aquisição do aparelho. Realizou-se a mensuração da intensidade de luz utilizando-se umradiômetro (Demetronri). Os dados foram submetidos à análise descritiva. Concluiu-se que 10%dos fotopolimerizadores avaliados estavam com intensidade de luz acima de 400 mW/cm2; 76,65%dos aparelhos estavam com intensidade de luz abaixo do adequado para polimerização das resinascompostas; o tempo de 20 segundos de polimerização da resina composta foi o mais empregado;88,8% dos profissionais realizaram a limpeza do fotopolimerizador após cada procedimento e48,33% dos profissionais aplicaram a luz apenas pela oclusal.


The aim of this study was to evaluate the curing devices on private practice officesusing a radiometer, and also to examine the maintenance made on these devices. It was evaluatedsixty light curing units in private practice offices on Caruaru-PE. All the dentists participatedof the evaluation as voluntaries and were not identified on the questionnaire that was presentedto them. It was asked witch clean methods and kind of maintenance they used on their devices,the frequency of these procedures, if the dental surgeons were satisfied with their curing lightunits, the level of knowledge and actualization by the dentist about the studied theme, and thetechnique of polymerization used. The evaluation of the devices were made getting note of theinformation about the kind and diameter of the curing light tip, witch was the model and markof the devices, the age of the unit, and also it was measured the light intensity using a radiometer(Demetronri). The acquired data of this study were submitted to a descriptive analysis. Based onthe employed methodology and on the found results could be concluded that only 10% of the light curing devices evaluated were with the light intensity above 400 mW/cm2; it was also verifiedthat 76.65% of the curing units were with its light intensity under of the adequate level to make acomplete polymerization of resin composites; the composite resin was polymerized for 20 s forthe most dentists evaluated; 88.8% of the dentists cleaned the light cure unit after each procedureand 48.33% applied the light only over the oclusal surface.


Subject(s)
Composite Resins
10.
ROBRAC ; 11(31): 35-39, jun. 2002.
Article in Portuguese | LILACS, BBO | ID: lil-391809

ABSTRACT

O potencial cariogênico de alguns medicamentos infantis encontrados no mercado brasileiro, quando em contato com esmalte hígido, foi avaliado através de testes de microdureza. Os medicamentos testados foram: Amoxil, Clusivol e Glóbulos homeopáticos, comparados ao potencial cariogênico da sacarose. Voluntários, de baixo risco e ausência de atividade de cárie, utilizaram aparelhos intra-orais com fragmentos de esmalte fixados no palato e cobertos com uma rede de nylon com o objetivo de favorecer o acúmulo do biofilme. Cada voluntário aplicou um dos medicamentos citados acima por 30 dias, sendo que para o Amoxil, também foi avaliado o período de aplicação de 10 dias. Um grupo de controle foi estabelecido pela aplicação de água destilada sobre os fragmentos. A análise da dureza do esmalte foi realizada com diamante Vickers nas profundidades de 10, 20, 30, 50 e 70 um da superfície. Os dados foram submetidos a análise estatística de ANOVA e testes adicionais para comparação múltiplas, todos baseados em um nível de significância de 5 por cento. O grupo de controle (água destilada) apresentou os maiores valores de dureza para todas as profundidades, seguido pelo grupo Amoxil 10 e 30 dias e Clusivol apresentaram valores de dureza do esmalte comparável aos observados para o grupo da Sacarose. Os resultados permitiram concluir que todos os medicmentos avaliados, inclusive a droga antibiótica, favoreceram a colonização da superfície por microorganismos cariogêncios, resultando na desminerização superficial do esmalte


Subject(s)
Humans , Male , Female , Child , Dental Caries , Dental Enamel , Hardness , Sucrose
11.
Rev. odontol. UNESP ; 28(1): 49-61, jan.-jun. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-271336

ABSTRACT

Estudo da neoformaçäo óssea basal da mandíbula de 60 ratos, após preparo de um defeito obtido com fresa cilíndro-cônica, e preenchimento do leito ósseo de 30 ratos do grupo experimental com poliuretana vegetal acrescida de CaCO3. Para os 30 animais do grupo controle, o defeito ósseo näo recebeu nenhum tratamento. Aos 15, 25, 40, 60, 090 e 120 dias após a cirurgia, os animais foram sacrificados e suas mandíbulas removidas e coradas com hematoxilina e eosina, Picrosírius e tricrômico de Mallory para o estudo morfológico sob microscopia óptica comum e de polarizaçäo. Os resultados demonstram grande aceitaçäo orgânica à resina, näo ocorrendo formaçäo de cápsula, tampouco migraçäo local de células inflamatórias, além de o carbonato funcionar como isca, promovendo neoformaçäo óssea, estimulando o aparecimento das células osteogênicas


Subject(s)
Animals , Rats , Polyurethanes/administration & dosage , Polyurethanes/analysis , Resins/analysis , Mandible , Biocompatible Materials
12.
Rev. odontol. UNESP ; 28(1): 63-72, jan.-jun. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-271337

ABSTRACT

Estudo da neoformaçäo óssea basal da mandíbula de 40 ratos após preparo de um defeito ósseo obtido com fresa cilindro-cônica e preenchimento ósseo de 20 ratos do grupo experimental com poliuretano vegetal sem CaCO3. Os demais 20 ratos, representando o grupo controle, näo receberam nenhum tratamento. Decorridos 15, 25, 40 e 60 dias após a cirurgia, os animais foram sacrificados e suas mandíbulas removidas e coradas com hematoxilina e eosina para o estudo morfológico sob microscopia óptica comum. Os resultados demonstram grande aceitaçäo orgânica à resina, näo ocorrendo formaçäo de cápsula, tampouco migraçäo local de células inflamatórias


Subject(s)
Animals , Rats , Polyurethanes , Resins , Mandible , Biocompatible Materials
SELECTION OF CITATIONS
SEARCH DETAIL